top of page
Brownfield Heat Exchanger Installation

This project involved the conceptual design of a shell-and-tube heat exchanger installation within an existing process facility. The objective was to develop a practical brownfield piping arrangement that integrated with existing infrastructure while maintaining adequate access for operation and maintenance.
​
Project highlights:
-
Brownfield heat exchanger installation
-
Class 300 process piping
-
Class 150 cooling-water piping
-
P&ID, 3D model, GA, and isometrics
-
Instrumentation and control integration
-
Existing piping tie-ins
-
Constructability and maintenance-access considerations
Interactive Model
Take a closer look at the project using the interactive 3D model below. Rotate, zoom, and explore the design from any angle.
Selected deliverables developed for the project are attached below:​
General Arrangement
P&ID
Isometrics
bottom of page